| SETTINGS | CONNECTION | ADJUST | ADJUST FOR |
|---|---|---|---|
| VCO: Set radio to CH 20 AM RX mode. Clarifier setting in 12 o’clock. | Connect FC to IC3 Pin 8 | VC1 | Adjust for 10.24000MHz ±20Hz. |
| VCO: Set radio to CH 20 AM RX mode. Clarifier setting in 12 o’clock. | Connect DVM to TP2. | L14 | Adjust for 3.0 VDC ±0.1 |
| VCO: Set radio to CH 20 AM RX mode. Clarifier setting in 12 o’clock. | Connect Oscope to TP3 | L15 | Adjust for max. |
| AM Frequency: Set radio to CH 20 AM RX mode. | Connect frequency counter to TP3. | L20 | 16.51000 MHz ±20Hz. |
| SETTINGS | CONNECTION | ADJUST | ADJUST FOR |
|---|---|---|---|
| AM Sensitivity:Set radio to CH 19 AM RX mode. Set RF GAIN fully clockwise. Set SQ fully counter-clockwise. Set VOL Control at 2 o’clock. | Connect AF VTVM or scope across speaker terminals. Connect RF SG to antenna jack. Frequency 27.185 MHz, 1uV. Mod 30%. | (in order) L5,L6,L7,L8,L9,L10,L2,L3 | Audio Output > 2V S/N > 10 dB. Balance between CH 1 and CH 40 |
| Set radio to CH 40 AM RX mode. | RF SG setting 27.405 MHz. 100uV. Mod 30% | L5,L6 | For Balance Between CH 1 and CH 40. |
| Set radio to CH 1 AM RX mode. | RF SG setting 26.965 MHz, 100uV. Mod 30%. | L5,L6 | For Balance Between CH 1 and CH 40. |
| NB Adjust: Set radio to CH 19 AM RX mode Set switch to NB/ANL position. | RF SG setting 27.205 MHz, 100uV. Mod 30%. Connect Multi-meter to TP1 (D2 cathode). | L1 | DC Voltage to max.( > 2.0V ) |
| AM Squelch: Set radio to CH 19 AM RX mode. Set SQ Control fully clockwise. RF SG setting 27.185 MHz, 20mV. Mod 30%. | - | VR4 | Adjust very slowly until squelch just closes |
| AM S-Meter: Set radio to CH 19 AM RX mode. RF SG setting 27.185 MHz, 100uV. Mod 30%. | - | VR1 | For a reading of “9” on the “S” scale. |
| SETTINGS | CONNECTION | ADJUST | ADJUST FOR |
|---|---|---|---|
| AM OSC: Set radio to CH 19 AM TX mode. | Connect Frequency Counter to TP5. | L23 | 10.6950MHz ± 10Hz |
| TX Power: Set radio to CH 19 AM TX mode. Set SWR/MOD/PWR Switch to PWR. | Connect RF Power Meter to antenna jack. | L40,L42,L43,L44 | MAX > 12W Balance Power Between CH1 and CH40. |
| AM TX High Power: Set radio to CH 19 AM TX mode. Set RF POWER fully clockwise. | Same as above. | VR14 | 3.8 W |
| AM TX Low Power: Set RF POWER fully counterclockwise. | Same as above. | VR18 | 0.3W ±0.2W |
| RF Power Meter: Set radio to CH 19 AM TX mode. Set RF POWER fully clockwise. Set SWR/MOD/PWR Switch to PWR position. | - | VR9 | For a needle reading of “4” on TX PWR scale. |
| AM Modulation: Set radio to CH 19 AM TX mode. Set MIC Gain fully clockwise. | Connect AF SG to microphone input. AF signal 30mV, 1 KHz to microphone. | VR16 | For a needle reading of 90% on the external modulation meter. |
| AM Modulation Meter: Set radio to CH 19 AM TX mode. Set MIC Gain fully clockwise. Set SWR/MOD/PWR Switch to MOD position | AF signal 30mV, 1 KHz to microphone. | VR15 | For a needle reading of 90% on the modulation scale. |